• Profile photo of Ryan

      Ryan posted an update

      4 weeks ago

      Hello Docs,

      Looking for some guidance on restoring this case.

      The patient had these Astra EV implants placed by a periodontist. The plan with the then restorative dentist was CONUS attachments.

      The patient left the restorative dentist and came to us. He no longer wants to do CONUS or a bar overdenture due to finances.

      I was planning to fabricate locator overdentures and using MUAs to angle correct the posteiror implants. However, I am struggling to fine 30 degree MUAs that are tall enough (6-7mm tissue height on the distal of each implant ; but only 3-4mm on the mesial).

      Should I:

      – have tru abutment fabricate custom length MUAs

      – use shorter MUAs in the 2-3mm range and laser tissue away

      – something else?


      Thanks!