      Hello Docs,

      Looking for some guidance on restoring this case.

      The patient had these Astra EV implants placed by a periodontist. The plan with the then restorative dentist was CONUS attachments.

      The patient left the restorative dentist and came to us. He no longer wants to do CONUS or a bar overdenture due to finances.

      I was planning to fabricate locator overdentures and using MUAs to angle correct the posteiror implants. However, I am struggling to fine 30 degree MUAs that are tall enough (6-7mm tissue height on the distal of each implant ; but only 3-4mm on the mesial).

      Should I:

      – have tru abutment fabricate custom length MUAs

      – use shorter MUAs in the 2-3mm range and laser tissue away

      – something else?


      Thanks!

      • Would a lab be able to fabricate a custom abutment in a case like this?

        • @bmoore94 certainly could. I was between having Truabutment making custom MUAs or making custom locators

          I decided to just have them make custom locators to cut out the step of attaching locators to the custom MUAs

          TBD how it works out

          1
      • Thin out tissue ?

        • @nairysekayan considered it. Would be very frustrating to get him restored and have the tissue creep back up and prevent full seating of the prostheses though